Specifications
Main Unit |
| Part number |
95290-00500 |
| Package dimension |
2.24 width x 1.5 depth x 2.02 height (m) |
| Total weight in transport condition |
Approx. 1500kg |
| Main unit dimension |
1.76 width x 1.1 depth x 1.7 height (m) |
| Installing space |
3.8 width x 2.7 depth x 2.0 height (m) |
| Main unit weight |
Approx. 1100kg |
| Rated voltage |
Three phase voltages 200-220V (electric converter may be necessary.) |
| Frequency |
50/60Hz |
| Rated voltage |
150A (including the optional test oil cooler.) |
| Compression air pressure |
0.5~0.9MPa |
Amount of the compression air pressure be the
rated voltage in use |
50L/min (ANR) |
| Main Drive Unit |
| Rated output |
18.5kW |
| Rated output for 30 minutes |
22kW |
| Rotation speed input method |
By key/dialing |
| Rotation speed control range |
50~6000/min |
| Rotation angle control range |
0.1~180.0 |
| Flywheel inertial mass |
1.1kg/m2 |
| Miscellaneous Function |
| DC power for the pump (switch-over type) |
12/24V |
| Pump DC power capacity (maximum) |
3A |
| Test Oil Supply Unit |
| Applicable oil |
Equivalent of ISO 4113 (SAEJ967) |
| Tank capacity |
50L |
| Maximum supply capacity |
10L/min (at low pressure) |
| Pressure range |
9.8~343kPa (low pressure) 1.97~3.9MPa (high pressure) |
| Temperature control |
Available ( *1) |
| Temperature range setting |
30~50C (*1) |
| (*1) With the optional test oil cooler installed, the cooling capacity is 4.2kw. Tap water will be used when the oil cooler is not installed |
| Air Pressure Control Unit |
| Setting input method |
(by key) |
| Pressure range |
-80~200kPa |
| Lubrication Supply Unit |
| Tank capacity |
10L |
| Maximum supply capacity |
1L/min |
| Supply pressure range |
9.8~343kPa |
| Temperature control |
Not available |
| Measuring Unit |
| Injector nozzle connection |
12 locations |
| Injection volume shot counter |
1, 100, 200, 500, 1000 |
| Continuous flow volume measuring connection |
1 location |
| Continuous flow volume measuring range |
0.2~3.7L/min |